Insulated Glass Units is widely known and used in construction industry. Rather than stones or cement and wooden windows and doors, the IGU glass appearance and cost saving purpose leads to an advantage that win more people’s choices. It’s a product that uses two or more panels of glass are bonded to a perimeter spacer. Either air or argon gas fills the space between the glass panes. Their primary benefit is insulation and solar control. Can be combined with most types of glass into an insulated glass unit.
♦ COMF-E Optimum
COMF-E® Optimum é uma gama de unidades de vidro isolante (IGU) premium e altamente eficientes que utiliza uma ampla seleção de vidros Low-E, espaçadores e gases para atender às necessidades de desempenho de nossos clientes.
COMF-E Optimum é uma nova geração de unidades de vidro isolante (IGUs) da Landson Glass que oferece desempenho otimizado por meio de um revestimento de baixa emissividade.
Este produto foi especialmente projetado para minimizar a quantidade de calor que passa através do vidro.
O revestimento microscópico inteligente mantém o ambiente mais fresco no verão, refletindo o calor para fora, e mais quente no inverno, refletindo o calor de volta para dentro, sem comprometer a quantidade de luz que entra no espaço.


| Tipos de espaciadores | Aluminio, espaciador de bordo quente,aço, aço inoxidável |
| Espessura do espaçador | 6-27mm |
| Tipos de seladores | Fogo primário de PlB, Polisulfido, Fogo secundário de Silício |
| Tipos de vidro | Glass Float, Laminated, Toughened, Heat Strengthened and Pattern |
| Capacidade de processamento | 300 x 300-2700 mm x 5000 mm com espaciador de alumínio. Para unidades usando super espaciador, por favor ligue para discutir requisitos específicos de tamanho |
| Hora de líder | 2-3 semanas ex-fábrica |
| embalagem | Capas de madeira ou caixas podem ser feitas aos clientes requisitos. |
SPECIFICAÇÕES DE PERFORMANCIA
| INDIVIDADE MM |
SPECIFICAÇÃO | COLOR | Propriedades luminosas% | ENERGIA SOLAR% | VALOR RW | U VALOR | SHGC | SC | ||||||
| Trans | Refrescar | Refrescar | Trans | Rfsol | Rbsol | Abs1 | No Inverno | No Verão | ||||||
| COMF-E® OPTIMUM (Soft Coat) IGUs | ||||||||||||||
| 18 | COMF-E Optimum CSJ141(4/10/4)#2 | CLEAR-Single silver | 77.7 | 16.4 | 15.6 | 47.5 | 30.6 | 21.9 | 30 | 1.43 | 1.35 | 0.51 | 0.59 | |
| 18 | COMF-E Optimum CSJ141(5/8/5)#2 | CLEAR-Single silver | 79.5 | 13.0 | 12.5 | 51.8 | 25.5 | 22.7 | 30 | 1.48 | 1.62 | 0.57 | 0.65 | |
| 24 | COMF-E Optimum CSJ141(6/12/6)#2 | CLEAR-Single silver | 80.3 | 12.3 | 12.0 | 50.9 | 23.7 | 24.6 | 34 | 1.45 | 1.39 | 0.57 | 0.66 | |
| 24 | COMF-E Optimum GSX153(6/12/6)#2 | LIGHT GREY-Single Silver | 73.8 | 11.2 | 13.0 | 49.6 | 17.0 | 33.4 | 34 | 1.56 | 1.54 | 0.57 | 0.65 | |
| 24 | COMF-E Optimum CDJ138(6/12/6)#2 | CLEAR-Double silver | 69.6 | 13.0 | 14.0 | 33.3 | 33.0 | 31.3 | 34 | 1.45 | 1.39 | 0.38 | 0.43 | |
| 24 | COMF-E Optimum LI136(6/12/6)#2 | CLEAR-Double silver | 71.9 | 11.7 | 12.6 | 36.4 | 39.9 | 23.7 | 34 | 1.40 | 1.32 | 0.40 | 0.47 | |
| 24 | COMF-E Optimum NDX145(6/12/6)#2 | BLUISH GREY-Double Silver | 55.3 | 17.5 | 17.5 | 28.3 | 28.2 | 43.5 | 34 | 1.45 | 1.39 | 0.33 | 0.38 | |
| 24 | COMF-E Optimum LI144(6/12/6)#2 | BLUISH GREY-Double Silver | 47.0 | 15.0 | 12.0 | 21.8 | 43.9 | 34.3 | 34 | 1.41 | 1.34 | 0.25 | 0.29 | |
| 24 | COMF-E Optimum NDJ144(6/12/6)#2 | Neutral/Steel blue-Double Silver | 45.5 | 14.1 | 11.5 | 20.2 | 27.9 | 33.8 | 34 | 1.40 | 1.32 | 0.25 | 0.29 | |
| 24 | COMF-E Optimum CTJ134(6/12/6)#2 | Light Blue Green-Triple Silver | 68.3 | 13.4 | 14.0 | 26.2 | 37.0 | 43.6 | 34 | 1.36 | 1.27 | 0.30 | 0.34 | |
| 24 | COMF-E Optimum CTJ123(6/12/6)#2 | Light Blue Green-Triple Silver | 70.5 | 14.0 | 14.0 | 28.3 | 53.8 | 17.9 | 34 | 1.34 | 1.23 | 0.31 | 0.35 | |
| 24 | COMF-E Optimum Grey LI136(6GR/12Ar/6)#3 | GREY-Double Silver | 36.4 | 6.5 | 10.0 | 20.0 | 14.5 | 65.5 | 34 | 1.42 | 1.34 | 0.31 | 0.36 | |
| Note:
1. The above Performance Specifications are created using LNBL Windows 6.3 Software. External conditions according to ASHRAE NFRC100-2010 standard (US standard). 3. U Value based on Winter and Summer Climate. 4. To the best of our knowledge, all information is believed to be true and correct at time of compilation. |
||||||||||||||
Por favor, envie-nos e-mails, voltaremos para vocês o mais rápido possível.